
ABB CLMD capacitors
Dry-type low-voltage capacitors for panels and individual loads.
- Low-voltage PF correction
- For APFC panels and fixed banks
Genuine ABB, EPCOS and L&T stock, sized to your load and delivered just in time. We help plants, hospitals and commercial buildings hold their power factor near unity and stay clear of penalties.
Authorised dealer for
Pragati Enterprises is a Mumbai trading house and authorised dealer for energy-saving and electrical automation products from ABB, EPCOS, L&T, Suprimo, Vishay, Malde, Shreem, Beluk and Neptune.
Our range covers power capacitors, APFC relays and panels, detuned reactors, thyristor modules, active filters and HT capacitor banks, along with contactors, timers, meters, load managers, load analysers and surge arrestors.
To be among the leading suppliers of electrical goods to industry: a one-stop shop for reliable, value-for-money products that keep sites safe, cut costs and perform as promised.
To grow alongside our customers, employees and vendors by supplying genuine, quality products backed by the best service we can give. We buy only from reliable sources, and measure success by our customers' benefit.
| Type | Trading house and authorised dealer |
|---|---|
| Location | Mulund (W), Mumbai |
| Brands | 9 authorised, more on request |
| Range | LT and HT capacitors, APFC, harmonics, energy saving |
| Support | Sizing help and just-in-time delivery |
| Led by | Jignesh Mehta |
Pick the problem you're seeing at site. The readout shows what usually fixes it and which products to look at. Our team confirms sizing before you order.
Your plant draws more current and more kVA than the real work needs. An APFC panel switches LT capacitor steps in and out as the load changes, holding power factor close to unity.
Drives, UPS systems and rectifiers inject harmonics that resonate with plain capacitors and age them fast. A detuned reactor in series with each step blocks the resonance.
Contactors cannot keep up with welding, cranes, presses or lifts, and wear out trying. Thyristor switching responds instantly without inrush, up to 690 V.
When distortion trips sensitive equipment or fails an audit, an active filter measures it and injects an equal and opposite current to cancel it.
For HT consumers, correction is built from 50 to 1,000 kVAr units rated 1 to 22 kV, connected in star, double star or delta to suit your protection scheme.
We supply replacement capacitors, APFC relays, capacitor duty contactors and thyristor modules across brands, matched to what is already installed.
Power factor correction cuts the current your plant draws for the same work: cooler cables, lower kVA demand and electricity bills without PF penalties.
Enter the load and power factor from your electricity bill. The test bench shows the kVAR you need and what correction does to current and kVA.
Move the faders or type your load.
Indicative only. Final sizing depends on your load pattern and harmonics, so our team confirms it before you order.
Turn the selector to switch range. Most products are available across several brands, so we can match your specification and budget.

Dry-type low-voltage capacitors for panels and individual loads.

Compact LV capacitor units for building APFC panels and fixed banks.

Heavy-duty capacitors for demanding duty cycles and detuned panels.

Economical capacitors for standard power factor correction.

More choice on rating, budget and delivery from one supplier.

Motor-run and fan capacitors for pumps, motors and fans.

Touchscreen APFC relay that sets itself up and protects your capacitors.

Power factor correction relays for all standard applications.

Central reactive power compensation with harmonic mitigation.

Fast, transient-free switching for loads that change in seconds.

Standard and fast devices for thyristor-switched panels.

Contactors built to handle capacitor switching inrush.

Three-phase inductors that stop capacitors amplifying harmonics.

Measure and cancel harmonic currents in real time.

Static compensators for dynamic reactive power correction.

Building blocks for high-voltage capacitor banks.

Series-parallel banks for 3.3 kV up to 220 kV systems.
Send your single-line diagram and kVAr requirement for a configuration and quote.

Full brightness in microseconds at a fraction of the power.

V-Guard V-Hot series, hot water in every season.
The rest of the panel, from the same supplier.
Can't find a rating or model? Send us your requirement and we'll source it.
From the capacitor to the meter that monitors it. Tap any line to enquire.
Each breaker closes as the step completes. Scroll on.
Send electricity bills, connected load or the model you need.
We check load pattern and harmonics, and suggest a site measurement where needed.
Correctly sized kVAR with brand options, quoted from current pricelists.
Genuine products delivered just in time for your project or breakdown.
Help installing capacitors and commissioning, plus after-sales support.
Capacitor units from 50 to 1,000 kVAr at 1 to 22 kV, combined in series and parallel and connected in star, double star or delta to suit your protection scheme.
Banks rated between 2 and 24 MVAr supplied. Units are type tested to IEC and IS 13925 at CPRI, an NABL-accredited laboratory.
Hover or tap a nameplate to see what we supply from each brand.
Also supplied: Nippen APFC relays and V-Guard solar water heaters. Need another make? Ask us.
Six things our customers tell us matter most when power quality equipment has to be right first time.
Genuine products through authorised channels only
Quoted from current brand pricelists, against your exact specification
Just-in-time supply for projects and breakdown replacements
Help sizing capacitors, panels and reactors for your load
Multiple payment modes accepted
Nine authorised brands and 18 product lines, compared in one quote
Wherever motors, drives and lighting run all day, power factor correction pays for itself. Hover or tap an industry to see what it typically needs.
Spinning and weaving lines run heavy motor and drive loads around the clock.
Machine shops, process plants and assembly lines.
UPS and imaging loads create harmonics; supply must stay clean.
Campuses, hostels and labs with mixed loads.
Server rooms, UPS and precision cooling.
Malls and offices with HVAC, lifts and escalators.
Small and mid-sized units on LT supply.
Cranes, hoists and welding sets on site supply.
Download product catalogues directly. Pricelists are sent on request so you always get the current one.
| Document | Brand | Type | Action |
|---|---|---|---|
| PDFABB CLMD capacitors | ABB | Brochure | Download |
| PDFABB QCap LV capacitors | ABB | Catalogue | Download |
| PDFABB QCap-L LV capacitors | ABB | Brochure | Download |
| PDFABB RVC power factor controller | ABB | Pamphlet | Download |
| PDFEPCOS power capacitors | EPCOS | Catalogue | Download |
| ABB pricelist | ABB | Pricelist, sent on request | |
| EPCOS pricelist | EPCOS | Pricelist, sent on request | |
| Another catalogue | Any brand | On request | Ask us |
Yes. Pragati Enterprises is an authorised dealer for ABB, EPCOS, L&T, Suprimo, Vishay, Malde, Shreem, Beluk and Neptune. Everything we supply comes through authorised channels.
kVAR required = kW × (tan φ₁ − tan φ₂), where φ₁ is your present power factor angle and φ₂ the target. Taking a 100 kW load from 0.72 to 0.99 needs about 82 kVAR. Try the kVAR calculator.
Send us 6 to 12 months of bills and we will size it for your real load pattern.
Most plants target 0.95 to 0.99. Fixed capacitors sized for full load can push power factor leading when load drops, which is why an APFC panel switches steps in and out.
When a sizeable share of your load is non-linear: VFDs, UPS systems, rectifiers or LED drivers. Their harmonics can resonate with plain capacitors. Detuned reactors in series prevent that.
Contactor switching suits loads that change gradually and is economical for most plants. Thyristor switching responds instantly without inrush, for welding, cranes, presses and lifts.
Yes. Replacement capacitors, APFC relays, capacitor duty contactors and thyristor modules across brands. Share the nameplate details or a photo and we will match it.
Yes. HT units from 50 to 1,000 kVAr at 1 to 22 kV, and banks from 3.3 kV to 220 kV in star, double star or delta, rated 2 to 24 MVAr.
Request it from Downloads. We send the current ABB and EPCOS pricelists to your email or WhatsApp.
Send us your last electricity bill. We'll size the correction and quote from current pricelists.
Include kVAR, voltage or the model number if you have them.
We'll send the ABB and EPCOS pricelists to you.